| Voltage DC | Range | 6.000 V – 1000 V |
| Best accuracy | ±(0.3% + 1) | |
| Best resolution | 0.1 mV | |
| Voltage AC | Range | 600.0 mV – 1000V |
| Best accuracy | ±(2.0% + 2) | |
| Best resolution | 1.0 mV | |
| Amps AC | Range | 60.00 mA – 10 A |
| Best accuracy | 2.5% + 2 | |
| Best resolution | 0.01 mA | |
| Amps DC | Range | 60.00 mA – 10A |
| Best accuracy | 1.5% + 2 | |
| Best resolution | 0.01 mA | |
| Resistance | Range | 600.0 Ω – 50 MΩ |
| Best accuracy | ±(0.5% + 1) | |
| Best resolution | 0.1 Ω | |
| Capacitance | Range | 1nF – 9,999 μF |
| Best accuracy | ±(1.2% + 2) | |
| Best resolution | 1 nF | |
| Frequency | Range | 99.99Hz – 99.99kHz |
| Best accuracy | ±(0.1% + 1) | |
| Best resolution | 0.01 Hz | |
| Maximum Voltage between any Terminal and earth ground | 1000 V | |
| Surge protection | 8 kV peak per IEC 61010 | |
| Ω Fuse For mA inputs | 440 mA, 1000 V FAST Fuse | |
| Ω Fuse For A inputs | 11 A, 1000 V FAST Fuse | |
| Display | Digital | 6000 counts, updates 4/sec |
| Bar graph | 33 segments, updates 32/sec | |
| Frequency | 10,000 counts | |
| Capacitance | 1,000 counts | |
| Altitude | Operating | 2,000 Meters |
| Storage | 12,000 Meters | |
| Temperature | Operating | -10°C to + 50°C |
| Storage | -40°C to + 60°C | |
| Temperature coefficient | 0.1 x (specified accuracy / °C (< 18°C or > 28°C) | |
| Electromagnetic compatibility | In an RF field of 3 V/M, accuracy = specified accuracy except in Temperature: | |
| (EN 61326–1:1997) | specified accuracy ±5°C (9°F) | |
| Relative humidity | 90% to 35°C | |
| (Maximum Non-condensing) | 75% to 40°C | |
| 45% to 50°C | ||
| Battery life | 400 hours typical (alkaline) | |
| Size (H x W x L) | 4.3 x 9 x 18.5 cm | |
| Weight | 420 g | |