AC Current |
|
Range |
600.0 A |
Resolution |
0.1 A |
Accuracy |
2 % ± 5 digits (48 – 62 Hz) |
Crest Factor (50/60 Hz) |
2.5 @ 600 A |
AC Voltage |
|
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
1.0 % ± 5 digits (48 – 62 Hz) |
DC Voltage |
|
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
1 % ± 5 digits |
Resistance |
|
Range |
600.0 Ω/6000 Ω |
Resolution |
0.1 Ω/1 Ω |
Accuracy |
1 % ± 5 digits |
Continuity Beeper |
30 Ω |
Capacitance |
|
Range |
10.0 – 100.0 μF / 1000 μF |
Resolution |
0.1 μF/1 μF |
Accuracy |
1.9 % ± 2 digits |
Mechanical Specifications |
|
Size (L x W x H) |
232 mm x 85 mm x 45 mm |
Weight |
370 g |
Environmental Specifications |
|
Operating Temperature |
-10 °C to +50 °C |
Storage Temp |
-40 °C to +60 °C |
Operating Humidity |
Non condensing (< 10 °C) |
|
≤ 90 % RH (at 10 °C to 30 °C) |
|
≤ 75 % RH (at 30 °C to 40 °C) |
|
≤ 45 % RH (at 40 °C to 50 °C) |
|
(Without Condensation) |
Operating Altitude |
3000 Meters |
Storage Altitude |
12,000 Meters |
EMI, EMC |
Meets All applicable requirements in EN61326-1:2006 |
Temperature Coefficients |
Add 0.1 x specified accuracy For each degree C above 28 °C or beLow 18 °C |
Safety Compliance |
ANSI/ISA S82.02.01:2004 |
|
CAN/CSA-C22.2 No. 61010-1-04 |
|
IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV |
|
Pollution Degree 2 |
|
EN/IEC 61010-2-32:2002 |
|
EN/IEC 61010-031:2002/A1:2008 |
Batteries |
2 AA, NEDA 15A, IEC LR6 |